original new KIC X5 7CH Channel Temperature Curve Tester online

Sistema del canal 1 de KIC X5 7CH
MOQ
KIC X5 7CH Channel exw price is 6300usd/set
Precio
original new KIC X5 7CH Channel Temperature Curve Tester online
Caracteristicas Galería Descripción de producto Pida una cita
Caracteristicas
Especificaciones
Marca:: Canal de KIC X5 7CH
Uso:: Industrial, prueba de perfil del temeperature del horno del flujo
Teoría:: Registrador de la temperatura
Exactitud:: ±0.5℃ (completo), ±0.5℃ (completos)
Gama de temperaturas:: -150℃~1050℃
Resolución:: 0.3C variable a 0.1C
Temporeros de funcionamiento internos:: 0C a 105C
Frecuencia de muestreo:: 0,1 a 10 por segundo
Marca:: Profiler la termal de SMT
Skype: sensenhenhao
WhatsApp: +8613424013606
WeChat: JoyLY0322
Correo electrónico: joy@meraif.com
Página web: https://www.meraif.en.alibaba.com
Información básica
Lugar de origen: LOS E.E.U.U.
Nombre de la marca: KIC X5 profiler
Certificación: CE
Número de modelo: Canal de KIC X5 7CH
Pago y Envío Términos
Detalles de empaquetado: Profiler de KIC X5 que embala con el caso de madera
Tiempo de entrega: Canal de KIC X5 7CH en el plazo de 15 días después del pago
Condiciones de pago: TT, unión occidental, PayPal y así sucesivamente
Capacidad de la fuente: 300 sistemas por el canal del mes KIC X5 7CH
uso: Industrial, prueba de perfil del temeperature del horno del flujo
Teoría: Registrador de la temperatura e instrumentos analíticos
Descripción de producto

original new KIC X5 7CH Channel Temperature Curve Tester online

whats-app:+86134-24013606,skype:sensenhenhao

 

 

We are the Authorized Distributor of KIC

Temperature Curve Tester KIC X5 profiler Specifications:

KIC X5 Profiler
7 Channels : 206X60X17mm
9 Channels : 206X75X17mm
12 Channels : 206X98X17mm

 

Intelligent Thermal Profiler

 

Robust Hardware – Ease of Use – Process Optimization
2 Year Warranty – 24 Hour Word Class Customer Support

 

KIC X5 thermal profiler Robust and Compact Hardware

 

This new and improved hardware is designed to withstand the roughest and toughest daily handling! The electronic circuitry is designed to tolerate a high level of voltage spikes that occasionally occur in some ovens and wave solder machines.

 

KIC is putting their money where their mouth is by offering a standard TWO YEAR warranty on this durable profiler.

 

The X5 is availalbe in 7, 9, and 12 channel versions using standard type K thermocouple connectors and uses standard AAA or recharageable batteries. Additionally you can power the X5 via the USB cable when connected to a computer. Get better data to precisely identify what is going on with each thermal profile and process in the factory.

 

KIC X5 thermal profiler Data Intelligence Software

 

The X5 software uses a modern, graphical interface that quickly and intuitively guides you through the task of profiling. Manual prediction capability comes standard with the X5, allowing you to manually adjust and improve upon your process or oven setup. The Navigator PowerTM software feature automates process improvements and optimization for you and ships standard with the X5Within seconds, the Navigator Power will identify the single best oven setup.

 

The X5 also comes standard with SPC charting software that helps reveal changes in the profile over time.

 

The X5 hardware and software establish a new generation of profiler to improve your production quality, productivity, and documentation.

 

KIC X5 thermal profiler Technical Specifications

 

1.Accuracy: ±1.2C


2.Resolution: Variable 0.3C to 0.1C

 

3.Internal Operating Temp: 0C to 85C


4.Thermocouple Compatibility: Type K, 6 channels


5.Temperature Range: -150C to 1050C


6.Power Requirements: Standard 9V alkaline battery

 

7. Data Points: 224,640


8.Dimensions: See Temperature Tolerance Chart below for specifications

 

9. Sample Rate: 0.1 to 10 per second

Datalogger Model: data is downloaded to the computer through a cable after the run.
Dual Unit Model:data is sent to the computer in real-time during the run. It is also stored internally for high-speed download after the run.

Computer Configuation

Minimum System Requirements

        1.When KIC 2000 Software is running on the same computer as the Oven software, and/or when additional KIC 2000 Software options are installed, a faster CPU and more RAM may be required.

        2.A USB to Serial Adapter may be required to connect the SlimKIC 2000 for profiling.

        3.Contact KIC for issues with operating systems other than those listed.

400 MHz Processor, Celeron / 128 Mb RAM1
1 Gb available storage (for product history)
Video 1024 x 768 resolution / 16-bit
1 available serial port or USB port2
1 available parallel port or USB port for software key options
soft® Windows® 2000 or XP3

 

KIC X5 thermal profiler picture show: